从循环水主管引出一定比例旁流水,通过过滤器持续去除悬浮物、泥沙、锈渣和浊度,保护换热器与末端设备。
A portion of circulating water is diverted through filters to continuously remove suspended solids, sand, rust and turbidity, protecting heat exchangers and terminal equipment.
A portion of circulating water is diverted through the filter to continuously remove suspended solids, sand, rust and turbidity, protecting heat exchangers and terminal equipment.
循环水旁流净化 / Side-stream purification
采用旁路循环方式,过滤后的水回流系统;通过压差、时间或手动方式触发排污/清洗,使系统长期保持低颗粒负荷。
Using side-stream circulation, filtered water returns to the system. Blowdown or cleaning can be triggered by differential pressure, time or manual operation to keep particle loading low.
冷却塔循环水 / 开式循环水 / 数据中心循环水旁滤 / 换热器保护
Customized for data center water systems, retrofit projects and overseas delivery.
郅奕可根据项目现场接口、控制系统、数据中心运维标准和海外交付要求,提供P&ID、I/O清单、控制逻辑、操作说明、调试报告和备件建议。
| 服务模式 | 设计选型 / 制造集成 / FAT / 现场调试 / 运维支持 |
|---|---|
| 控制方式 | 手动、本地自动、PLC/HMI、Modbus/远程预留 |
| 交付形式 | 模块化撬装,适合国内项目与海外出口包装 |
| 适用行业 | 数据中心、半导体、电子、工业循环水与纯水系统 |